Sinktops

Moulded Double Drainer Sinktops

These sinktops are moulded as homogeneous items and as such are totally seamless. Sinktops  include an integrally moulded central sink bowl, sloping drainers to both sides and moulded edging . A flat area is provided to the rear of the sink on which to mount any taps required. It is possible to cut and re-edge the sink-units to give a reduced width.

All of these sink-units have raised drainer rails. Please note that the design of each unit is slightly different. 

Detailed drawings can be supplied on request.

Sinktops can be mounted directly onto steel supports or whatever furniture is being used. We would recommend full peripheral support with the addition of supports either side of the bowl.

Moulded Double Drainer Sinktops - Product Dimensions

Sinktop Ref. Length Width Bowl Size Waste Location Weight PDF DWG
DD1350 1350 mm 760 mm. 600 x 450 x 250 mm. Rear 30 kg
DD1500 1500 mm. 750 mm. 450 x 365 x 200 mm. Rear 30 kg
DD1500(F) 1500 mm. 650 mm. 450 x 365 x 200 mm. Rear 28 kg
DD1500(X) 1500 mm. 750 mm. 600 x 450 x 250 mm. Rear 35 kg
DD1650(F) 1650 mm. 650 mm. 635 x 370 x 270 mm. Rear 35 kg

Our standard colours are:

The colours shown on this website are a guide only and cannot be guaranteed to match the colour of components supplied by Simmons.

Grey

White

White

Cream

Black

Black

Dark Grey

Chemical Resistance

(24 hour sport test. Based on BS EN 438-2:1991).

Acetone

Unaffected

Acetonitrile

Unaffected

Ammonium Hydroxide – 28%

Unaffected

Aqua regia

Unaffected

Benzyl alcohol

Unaffected

Chloroform

Unaffected

Chloroform – 100%

Unaffected

Chromic acid pickle (*1)

Unaffected

Dicholoromethane

Surface attack

Dimethylformamide

Unaffected

Ethyl acetate

Unaffected

Formaldehyde – 37%

Unaffected

Hydrochloric acid – 30%

Unaffected

Hydrochloric acid – concentrated

Unaffected

Hydrofluoric acid – 40%

Slight bleaching

Hydrogen Peroxide

Unaffected

Methanol

Unaffected

Nitric acid – 70%

Very slight bleaching

Nitric acid – concentrated

Slight yellowing

Nitric acid – fuming

Attack and staining

Perchloric acid – 0.1N

Unaffected

Phosphoric acid – concentrated

Unaffected

Potassium hydroxide pellet (*2)

Unaffected

Sodium hydroxide – 50%

Unaffected

Sodium hydroxide pellet (*2)

Unaffected

Sodium hypochlorite

Unaffected

Sulphuric acid – 70%

Unaffected

Sulphuric acid – concentrated

Surface attack

Xylene

Unaffected

Mechanical Properties

Tensile strength

85 N/mm²

Tensile Modulus

10,500 N/mm²

Elongation at break

0.8%

Flexural strength

112 N/mm²

Flexural Modulus

10,000 N/mm²

Compressive strength

190 N/mm²

Coefficient of linear thermal expansion

34 x 10⁶

Water absorption – 24 hours at 23ºC

5–10 mg (0.06–0.068%) ISO 62 (1980)

Thermal Properties

Thermal Shock

2000 cycles (90 sec. at 75ºC, 90 sec. dwell, 90 sec. at 15ºC)
No effect
Should not be used with dry-ice or liquid nitrogen

Smoke Emission

Low Smoke Emission – BS 6853 1999 App. D Clause d.8.4
Result – Ao(on) 8.75, Ao(off) 10.41

Flammability

Class 0

Thermal Decomposition

350ºC

Glass transition temperature (Tg)

120 – 130ºC

Radioactive Decontamination

Decontamination factor (geometric mean)

5598.0

Deviation factor

1.25

Ease of radioactive decontamination classification

"Excellent"

Installation and Maintenance

General Maintenance

As with all worktops a reasonable standard of laboratory housekeeping will help to keep the worktops in good condition. All spillages should be cleaned up as soon as possible. Staining agents and aggressive chemicals should not  be allowed to sit in contact with the tops for a prolonged period of time.

Areas of chemical attack or staining can be removed with a polishing compound or very fine abrasive paper, but it should be stressed that this will alter the finish of the surface. Performance will not be affected.

The use of a wax furniture polish will help to retain the gloss finish.

Components should not be exposed to dry-ice or liquid nitrogen and heat insulation pads should be placed between a top and a steambath or hotplate to prevent thermal stress.

Wastes and overflows

Sinks can be supplied complete with a chemically resistant polypropylene waste in grey, white or black is required. Wastes have a 73mm diameter flange and a 1½ inch BSP tail and will connect to the relevant Vulcathene industrial waste components. These can also be combined with a standing waste tube or an overflow kit.